Huawei HCIP-Transmission V2.0 - H31-341 Exam Practice Test

Which of the following are limitations of the alarm and performance analysis methods? (Multiple Choice)

Correct Answer: A,B Vote an answer
In the WDM system, what is the reason for the fiber attenuation and bit error rate? (Multiple Choice)

Correct Answer: A,B,C Vote an answer
Which of the following description of the performance parameters of line fiber quality monitoring is wrong?

Correct Answer: D Vote an answer
The user-oriented interface and the interface for the transport network of the E-Line service are
____ and _____.

Correct Answer: B Vote an answer
Which of the following statement is correct?

Correct Answer: B Vote an answer
If you want to establish a GE-level path on the NMS, which of the following steps are required? (Multiple choice)

Correct Answer: A,B,C,D Vote an answer
The optical and electronic shelves of the OSN 9800 are connected through the master-slave subrack cascading mode and connected through the GE 1/2 port on the CTu board.

Correct Answer: B Vote an answer
TEM28 is the Ethernet convergence tributary board. Which of the following descriptions about the TEM28 board are correct? (Multiple Choice)

Correct Answer: A,B,C,D Vote an answer
The OSN 8800 device is protected by fan redundancy. When any fan in the fan box is broken, the system can still operate normally for a long time.

Correct Answer: A Vote an answer
The length range of the DATA field in the Ethernet frame structure is ().

Correct Answer: A Vote an answer
Before querying the error and optical power on the network management, you need to perform the () operation. Otherwise, you cannot query the corresponding teaching data.

Correct Answer: A Vote an answer
What should I pay attention to when commissioning a 100G and 10G hybrid transmission system? (Multiple Choice)

Correct Answer: A,B,C,D Vote an answer
Path method creates OCh failure, what are the possible reasons? (Multiple Choice)

Correct Answer: A,C,D Vote an answer
When you delete a discrete service, you can first activate it. At this time, you can view the alarm. If there is no alarm such as PS or TU-AIS, it is a garbage service. If there is an alarm, the analysis is incorrect. You need to activate it immediately.

Correct Answer: B Vote an answer

Contact Us

If you have any question please leave me your email address, we will reply and send email to you in 12 hours.

Our Working Time: ( GMT 0:00-15:00 ) From Monday to Saturday

Support: Contact now 

日本語 Deutsch 繁体中文 한국어