Updated Nov-2022 Exam Engine for NS0-593 Exam Free Demo & 365 Day Updates [Q25-Q46]

Share

Updated Nov-2022 Exam Engine for NS0-593 Exam Free Demo & 365 Day Updates

Exam Passing Guarantee NS0-593 Exam with Accurate Quastions!


NetApp NS0-593 Exam Topics:

SectionObjectives
Protocols- Demonstrate knowledge of ONTAP NAS configurations
- Demonstrate knowledge of ONTAP SAN configurations
- Demonstrate knowledge of S3 server configurations
Software-defined ONTAP Solutions- Describe software-defined ONTAP solutions


NetApp NS0-593 Exam Certification Details:

Duration120 minutes
Number of Questions60
Exam RegistrationPEARSON VUE
Sample QuestionsNetApp NS0-593 Sample Questions
Passing Score62%
Recommended TrainingONTAP Troubleshooting (ILT)
Exam Price$150 USD

 

NEW QUESTION 25
You have a 2-node NetApp FAS2750 switchless cluster with twenty-four 1.8 TB disks that is experiencing
performance issues. Upon investigation, you discover severaltype B consistency points.

Referring to the exhibit, which corrective action would address these consistency points?

  • A. Replace the twenty-four 1.8 TB disks with twelve 4 TB disks.
  • B. Add an additional shelf oftwenty-four 1.8 TB disks.
  • C. Convert the 2-node switchless cluster to a 2-node switched cluster.
  • D. Create additional data LIFs.

Answer: B

 

NEW QUESTION 26
Your customer complains about missing volume snapshot copies on a SnapMlrror destination. While
investigating this case, you notice an executed SnapMirror resync operation in the event logs of the system.
In this scenario, what Is the cause of this problem?

  • A. Newer Snapshot copies than the common snapshot that was chosen for resync were removed
    automatically at the destination.
  • B. Snapshot copies were manually removed from the destination after the resync.
  • C. The autodelete option removed Snapshot copies before the resync.
  • D. NetApp ON TAP System Manager removed these snapshot copies due to a snapshot schedule.

Answer: B

 

NEW QUESTION 27
A system panic due to an "L2 watchdog timeout hard reset" error occurred. You have found a FIFO message
in the SP log.
Which FIFO message Is useful for Investigating this Issue?

  • A. ONTAP Shutdown BBSP:C=00 L=2F FIFO:
  • B. BIOS exit BBSP:C=2F L=20 FIFO: 2 C8 C9 C4 24 4 6 18 7 8 11
  • C. before NMI BBSP:C=00 L=00 FIFO: F3 F2 F1 F0 5 B2 0 0 0 80 20 E F E3 C0 C2 3 4 6 7 9 9 A
  • D. before Reset BBSP:C=00 L=00 FIFO:

Answer: B

 

NEW QUESTION 28
Your customer calls you because one application is not able to access a NetApp ONTAP S3 bucket. While
reviewing the EMS log on the cluster, you see the following message:

The same credentials work in another application.
In this scenario, what would cause this problem?

  • A. The application is using v4 signatures.
  • B. The application is trying to access using the HTTP protocol.
  • C. The application is using v2 signatures.
  • D. The application is trying to log in as an anonymous user.

Answer: D

 

NEW QUESTION 29
Your customer Informs you about SnapMlrror problems after upgrading NetApp ONTAP software to a newer
version. After investigating the event logs and the SnapMirror history, you see information about delayed
updates of the SnapMirror relationships.
How would your customer prevent such problems in the future?

  • A. Verify that the cabling of the hardware port that Is responsible for SnapMirror transfers Is correct.
  • B. Modify the schedules of the SnapMirror relationships after upgrading the ONTAP software.
  • C. Delete the SnapMirror relationships and create them new after upgrading the ONTAP software.
  • D. Quiesce the SnapMirror relationships before upgrading the ONTAP software.

Answer: A

 

NEW QUESTION 30
You created a new NetApp ONTAP FlexGroup volume spanning six nodes and 12 aggregates with a total size
of 4 TB. You added millions of files to the FlexGroup volume with a flat directory structure totaling 2 TB, and
you receive anout of apace error message on your host.
What would cause this error?

  • A. All constituent volumes are full.
  • B. The inode limit is exceeded in the ONTAP software.
  • C. The maxdirsize Is exceeded in the ONTAP software.
  • D. The maximum number of volume constituents has been reached in the ONTAP software.

Answer: B

 

NEW QUESTION 31
You have recently discovered that NetApp ONTAP Cloud Manager is not sending AutoSupport messages to
NetApp.
In this scenario, what would solve this Issue?

  • A. Verify that the inbound and outbound rules allow AutoSupport on port 80.
  • B. Verify that your data LIFs allow traffic to mysupport .netapp.com on port 443.
  • C. Verify that your AWScredentials are correctly added to Cloud Manager.
  • D. Verify that your NetApp Support site credentials are correctly added to Cloud Manager.

Answer: B

 

NEW QUESTION 32
You are trying to deploy a Connector in the AWScloud from NetApp Cloud Manager. The deployment fails
and shows the message 'Insufficient permissions to deploy Cloud Connector". You have verified the AWS
access key and the AWS secret key.
In this scenario, what Is the reason that the deployment failed?

  • A. The Connector can be deployed only inAWS GovCloud (US).
  • B. The user lacks the permission to deploy within Cloud Manager.
  • C. No AWS Marketplace subscription is associated with Cloud Manager.
  • D. The required Identity and Access Management (IAM) policies were not Installed.

Answer: B

 

NEW QUESTION 33
An administrator receives the following error message:

What are two causes for this error? (Choose two.)

  • A. There Is excessive SSD load causing the wear leveling to become unbalanced.
  • B. An SSD disk is performing garbage collection to create a dense data layout.
  • C. There is excessive SATA HDD load.
  • D. A disk is falling.

Answer: A,C

 

NEW QUESTION 34
Your customer added a new DS4246 shelf to their FAS2750 single-node system and created a new aggregate
on the new shelf. Two weeks later, they log into Active IQ and discover the Medium Impact error shown
below.
Shelves with both connections via the same SAS path detected

Referring to the exhibit, which statement is correct?

  • A. This situation is normal for a FA57750 single-node system.
  • B. In a FAS2750 system, the internal shelf is only seen on one path, and the external shelves are seen on
    two paths.
  • C. The cables are cabled Incorrectly on the SAS stack.
  • D. Active IQ Is not aware of the shelf configuration for a single-node system.

Answer: A

 

NEW QUESTION 35
A storage administrator reports that a monitoring toot is reporting that the storage controller reads between
90% to 93% CPU use. You run the sysstat -m command against thenode in question.

Referring to the exhibit, which statement is correct?

  • A. The CPU Is not a first-order monitoring metric for ONTAP.
  • B. The customer should be advised to exclude certain workflows to reduce use.
  • C. High network exempt use could be a problem.
  • D. You should immediately investigate further bygathering perfstat data and opening a support case.

Answer: D

 

NEW QUESTION 36
A customer's storage administrator Informs you about the deactivated Automatic Switchover (AUSO) feature
on their MetroCluster IP environment.
What Information would you tell your customer in this scenario?

  • A. The AUSO feature is not available in Metrocluster IP installations by design.
  • B. A faulty link automatically deactivated the AUSO feature.
  • C. This is a configuration failure, you can activate that feature for the customer.
  • D. The AUSO feature cannot be activated due to a non-mirrored aggregate.

Answer: D

 

NEW QUESTION 37
The motherboard of Node-01 is being replaced. To perform this task, a takeover was Initiated from Node-02.
Node-02 panics showing the string below.
PANIC; Permanent errors on all HA mailbox disks (while marshalling header) in SKprocess
fnmbx_instanceWorker on release 9.5P8 (C)
What has happened in this situation?

  • A. While in maintenance mode, the mailbox destroy local command was executed.
  • B. While in maintenance mode, the HA_config show command was executed.
  • C. While in maintenance mode, the sldiag device show command was executed.
  • D. While in maintenance mode, the fcadmin device_map command was executed.

Answer: D

 

NEW QUESTION 38
A customer wants to connect a NetApp AFF A700 system to a 40GbE switch. The controllers have a 10/40G
Ethernet card in slot 4 for this purpose. The link comes up fine on node 2,but it will not come up on node 1.
You look at the AutoSupport data for the nodes in question and see the output shown in the exhibit.

What is the cause of the customer's problem?

  • A. The cable is plugged in upside down.
  • B. The port has an incorrect SFP inserted.
  • C. The ports are configured for 4x10Gbit instead of 40Gbit.
  • D. The incorrect cable is used.

Answer: C

 

NEW QUESTION 39
You are optimizing your Cloud Volumes ONTAP. For interoperability and consolidation purposes, you need
to know the storagelimits.
In this scenario, which source should be reviewed?

  • A. Hardware Universe
  • B. Interoperability Matrix Tool (IMT)
  • C. NetApp Cloud Volumes ONTAP Release Notes
  • D. Cloud Central

Answer: C

 

NEW QUESTION 40
A customer reports that some of their client computers are unable to access a FlexGroup over CIFS. This
problem involves only their older Windows XP clients and some printers and scanners.
In this scenario, which statement Is correct?

  • A. FlexGroup requires CIFS shares to be located in qtrees, which these clients do not support.
  • B. FlexGroup requires CIFS shares to use the Continuously Available Feature, which these clients do not
    support.
  • C. These systems use the SMQI protocol which Is an unsupported feature in FlexGroup
  • D. These systems use Offloaded Data Transfer, which is an unsupported feature in FlexGroup.

Answer: B

 

NEW QUESTION 41
You have a customer complaining of long build times from their NetApp ONTAP-based datastores. They
provided you packet traces from the controller and client. Analysis of these traces shows an average service
response time of 1 ms. QoS outputconfirms the same. The client traces are reporting an average of 15 ms in
the same time period.
In this situation, what would be your next step?

  • A. A sync core should be triggered.
  • B. The cluster interconnects should be investigated.
  • C. The cluster is responding slowly and requires further investigation using performance archives.
  • D. The client that reports high latency should be investigated.

Answer: D

 

NEW QUESTION 42
After expanding a two-node AFF A300 cluster with two AFF A700 nodes, you observe latencies when data is
accessed indirectly. The system node run -node -command netstat command shows retransmits and packet
drops on the LIFs. The AFF A700 nodes with 40 Gbps and the AFF A300 connect with 10 Gbps to the cluster
interconnect. You are using Cisco Nexus 3132Q cluster interconnect switches. You just updated to ONTAP
9.8 software.
In this scenario, what is causing this problem?

  • A. The 10 Gbps to 10 Gbps cluster Interconnect is creating a speed mismatch.
  • B. The AFF A300 Is using an adapter card for the cluster Interconnect, but only onboard ports are supported.
  • C. AFF A300 and AFF A700 node mixing Isnot supported in ONTAP 9.8 software.
  • D. There is an NXOS firmware mismatch, verify in the Interoperability Matrix (1MTJ for a supportedversion.

Answer: A

 

NEW QUESTION 43
You recently discovered the error message shown below in your ONTAP logs.

What should be your first action to correct this Issue?

  • A. Use the wafliron command against my_data_vol to solve the inconsistency on the volume.
  • B. Power cycle all the disk storage shelves that contain drives of the aggregate with the my_data_vol
    volume.
  • C. Use the storage takeover command on the storage controller that contains my_data_vol.
  • D. Determine the root cause behind the inconsistency before attempting any recovery procedure.

Answer: B

 

NEW QUESTION 44
You are attempting to connect a NetApp ONTAP cluster to a very complex network that requires LIFs to fail
over across subnets.
How would youaccomplish this task?

  • A. Configure VIP LIFs using BGP.
  • B. Configure an equal number of UFs on each subnet.
  • C. Configure a I IF failover policy for each subnet inside a single broadcast domain.
  • D. Configure VIP LIFs using OSPF.

Answer: A

 

NEW QUESTION 45
Your customer has deployed a two petabyte NetAppONTAP FlexGroup volume across their 4-node ONIAP
9.8 cluster. They plan to store over three billion files. They want to prevent file 10 conflicts since files are
placed into the FlexGroup volume.
In this scenario, which two NFS SVM parameters should be enabled? (Choose two.)

  • A. -v3-64bit-identifiers
  • B. -v3-fsid-change
  • C. -v4-64bit-idantifiers
  • D. -v4-fsid-change

Answer: A,B

 

NEW QUESTION 46
......

Exam Questions for NS0-593 Updated Versions With Test Engine: https://www.fast2test.com/NS0-593-premium-file.html

Test Engine to Practice Test for NS0-593 Valid and Updated Dumps: https://drive.google.com/open?id=1GPz5HexD7qaWi5O076LylT2ElPJ5FaIs

Contact Us

If you have any question please leave me your email address, we will reply and send email to you in 12 hours.

Our Working Time: ( GMT 0:00-15:00 ) From Monday to Saturday

Support: Contact now 

日本語 Deutsch 繁体中文 한국어